Subject initiator:marcio.gomes       Replies:1       Published on:2021-12-27

Legends: ZTE engineer:Administrator
Subject:  ZXR10 3900A SNMP error
Common member
marcio.gomes

Common member
Score::3
Registered on:2014-05-27
ZXR10 3900A SNMP error (Published on:12/27/2021 9:40:04 PM)

Hi there...


I have some ZXR10 3900A that I trying insert into monitoring system... and can't get some data like: Serial Number from SNMP ... 
always returns (-1) value... :( (text below) 


And when trying walk (SnmpWalk)... return error (5)...


I know about the end-of-market??, service, etc... but I'm searching any idea about this proble?m and possible solutions... 
this is part of snmpwalk:






OID=.1.3.6.1.2.1.1.1.0 = "ZXR10 ROS Version V4.08.24R1 ZXR10_3928A-PS Software, Version ZXR10 3900E&3900A&3200A V2.8.23.B2.06.P17 Copyright (c) 2010-2015 by ZTE Corporation Compiled Jan 16 2012, 16:37:05" [ASN_OCTET_STR]
OID=.1.3.6.1.2.1.1.2.0 = "1.3.6.1.4.1.3902.3.100.418" [ASN_OBJECT_ID]
OID=.1.3.6.1.2.1.1.3.0 = "181284500" [ASN_TIMETICKS]
OID=.1.3.6.1.2.1.1.4.0 = "Contact-str" [ASN_OCTET_STR]
OID=.1.3.6.1.2.1.1.5.0 = "switch-name" [ASN_OCTET_STR]
OID=.1.3.6.1.2.1.1.6.0 = "Location-str" [ASN_OCTET_STR]
...
...
OID=.1.3.6.1.4.1.3902.3.1.1.0 = "418" [ASN_INTEGER]
OID=.1.3.6.1.4.1.3902.3.1.2.0 = "-1" [ASN_INTEGER]
OID=.1.3.6.1.4.1.3902.3.1.3.0 = "This is the rack information of ZXR10-3928A-PS" [ASN_OCTET_STR]
OID=.1.3.6.1.4.1.3902.3.1.4.0 = "0.0.0.0" [ASN_IPADDRESS]
OID=.1.3.6.1.4.1.3902.3.1.5.0 = "" [ASN_OCTET_STR]
OID=.1.3.6.1.4.1.3902.3.1.6.0 = "V4.08.24R1-ZXR10 3900E&3900A&3200A V2.8.23.B2.06.P17" [ASN_OCTET_STR]
...
...
OID=.1.3.6.1.4.1.3902.3.3.3.1.20.1.26, Type=Integer, Value=0
OID=.1.3.6.1.4.1.3902.3.3.3.1.20.1.27, Type=Integer, Value=0
OID=.1.3.6.1.4.1.3902.3.3.3.1.20.1.31, Type=Integer, Value=0
OID=.1.3.6.1.4.1.3902.3.3.3.1.20.1.32, Type=Integer, Value=0
OID=.1.3.6.1.4.1.3902.3.3.3.1.20.1.33, Type=Integer, Value=0
OID=.1.3.6.1.4.1.3902.3.3.4.1.1.1.1, Type=Integer, Value=1
OID=.1.3.6.1.4.1.3902.3.3.4.1.2.1.1, Type=Integer, Value=0
OID=.1.3.6.1.4.1.3902.3.3.4.1.3.1.1, Type=Integer, Value=0
OID=.1.3.6.1.4.1.3902.3.3.4.1.4.1.1, Type=Integer, Value=0
OID=.1.3.6.1.4.1.3902.3.3.4.1.5.1.1, Type=Integer, Value=0
OID=.1.3.6.1.4.1.3902.3.3.4.1.6.1.1, Type=Integer, Value=0
OID=.1.3.6.1.4.1.3902.3.3.4.1.7.1.1, Type=Integer, Value=0
%Failed to get value of SNMP variable. General Error (genErr(5))


I can't find anything about last firmwares updates, etc...


Any advice about Firmwares, MIBs, etc... or how to fix this problem?




Administrator
10103629

Administrator
Score::1722
Registered on:2010-06-22
Reply:ZXR10 3900A SNMP error (Published on:12/28/2021 3:35:39 PM)
3900A is not support  through SNMP to get  serial number ,and it's very old (EOS ), we do not support any more.




Total: 1 Records Page: 1 /1 First Prev Next Last    Records /Page(s)  
 
Subject:  ZXR10 3900A SNMP error
 Attachment  
 Reply Content